DSEG8600

Parallel generatorsetcontroller met geïntegreerde verwarming Door de gebruiker te configureren als: Single-Set Controller / Multi-Set Controller / Auto Mains (Utility) Failure Controller / Group Controller De G8600 is een parallel generatorsetcontroller met geïntegreerde verwarming, ontworpen voor complexe parallelle toepassingen. De G8600 kan worden geconfigureerd om tot 4.032 generatoren op één locatie parallel te schakelen en biedt een breed scala aan geavanceerde functies voor meerdere toepassingsomgevingen. De module is configureerbaar voor gebruik als single-set controller, multi-set controller, mains (utility) controller of group controller

Specificaties

SPECIFICATION DC SUPPLY Continuous Voltage Rating 8 V to 35 V DC continuous Cranking Dropouts Able to survive 0 V for 100 mS, providing supply was at least 10 V before dropout and supply recovers to 5 V. This is achieved without the need for internal batteries. LEDs and backlight will not be maintained during cranking. Maximum Operating Current 700 mA at 12 V, 350 mA at 24 V Maximum Standby Current 350 mA at 12 V, 190 mA at 24 V Charge Fail Excitation Range 0 V to 35 V Real Time Clock Battery Not replaceable VOLTAGE MEASUREMENT Measurement Inputs 3 ph + N Measurement Range 15 V to 415 V (L-N) / 25 V – 719 V (Ph-Ph) Accuracy 1% full scale Frequency Range 3.5 Hz to 75 Hz Input Impedance 450 K L-L CURRENT MEASUREMENT Measurement Inputs 3-phase & neutral Measurement Range 0-1 A, 0-5 A Max Allowed Continuous Current 5 A Accuracy 1% full scale Input Impedance 0.02 R INPUTS Analogue 4 sender inputs configurable 1 x 0-3 K, 3 x 0-5 K Digital (Flexible) 3 configurable, active low / active high, 0-3 K resistance, 0-10 V, 0-32 V, 0-20 mA Digital 9 active low digital outputs Type Standard senders with floating common, digital flex use system ground with separate return terminal Resolution 1 R, 0.1 V, 0.1 mA Accuracy 1% full range OUTPUTS Analogue Governor / AVR configurable ±10 V, ±20 mA Digital Fuel / crank protected FET output 15 A Auxiliary 8 protected FET @ 2 A Switching To Plant supply Volt-Free Contact 2 volt-free contacts (C & D) 8 A at 250 V AC AVR GOVERNOR CONTROL Minimum Load Impedance Voltage mode minimum = 500 R, Current mode max = 500 R Gain Voltage 0-10 V, 0-20 mA configurable Offset Voltage 0-10 V, 0-20 mA configurable MAGNETIC PICK-UP Voltage Input Range 0.5 V to 70 V RMS Frequency Input Range 1 Hz to 10 KHz Frequency Measurement Tolerance Better than 0.1% COMMUNICATIONS RS485 Fully isolated x 2 Ethernet 10/100 Ethernet Port USB A 1 x storage device USB B 1 x non isolated host / programming CAN Fully isolated x 3 TEMPERATURE Operating Temperature -30° C to +70 ° C / -22° F to +158 ° F Storage Temperature -40° C to +85 ° C / -40° F to +185 ° F DIMENSIONS Overall (W x H x D) 248 mm x 182.6 mm x 45.2 mm / 9.77” x 7.19” x 1.78” Panel Cut-Out (W x H) 220 mm x 160 mm / 8.66” x 6.3” Maximum Panel Thickness 8 mm / 0.31”

Video

Downloads

Blijf op de hoogte!
Schrijf je nu in voor onze nieuwsbrief!